Smarter Radiant Heating
Starts with TruHeat
Experience a new standard in radiant heat with the EZ-Heat system, engineered to outperform traditional systems with faster response times, superior efficiency, and reliable comfort under any floor type.
Features and Benefits
Advanced heating technology engineered for faster response, lower energy consumption, and long-term reliability.
Low Profile Design
Ultra-thin design installs quickly under virtually any floor type with minimal floor buildup.
Rapid Heat Response
Delivers fast, consistent warmth almost immediately with advanced low-mass heating technology.
Energy Efficient
Uses less energy and shorter run times to deliver efficient radiant comfort.
Primary Heat Source
Powerful enough to heat entire spaces as a reliable primary heating system.
15-Year Warranty
Backed by a comprehensive warranty for comfort, reliability and peace of mind.
Not Just Radiant Heat: A New Standard
EZ-Heat isn't just another radiant heating system, it's a more efficient way to heat your space. Engineered with advanced Amorphous Metal Tape technology, it delivers faster, more consistent heat while using significantly less energy than traditional cable or hydronic systems.
Designed to handle large areas with ease, EZ-Heat offers the performance of high-output systems without the high energy demands, making it one of the most efficient radiant heating solutions available today.
The difference comes down to how the system is built,
and why that design changes everything.
Rapid Heat Delivery.
Less Run-Time.
Driven by advanced Amorphous Metal Tape technology, the EZ-Heat system features an extremely low-mass heating element that requires very little wattage to rapidly reach its safe, optimal operating temperature of 30°C (86°F).
Unlike conventional radiant heating systems that take time to build heat and get up to temperature, EZ-Heat begins delivering effective warmth almost immediately. Because the system gets the job done faster, it doesn't need to run as long or as often, resulting in significantly lower run times, reduced energy consumption, and a level of efficiency traditional systems simply can't achieve.
Maximum Surface Contact. Better Heat Transfer.
At the core of EZ-Heat is a flat heating element that maximizes contact with the floor surface, unlike traditional round cables or pipes that limit heat transfer.
This increased contact allows heat to spread more evenly and reach the surface faster. Conventional systems, with minimal contact area, must operate at higher temperatures to be effective. EZ-Heat delivers consistent warmth more efficiently, resulting in improved performance and lower energy demand.
Ultra-Thin. Exceptionally Versatile.
With a slim 2.5 mm profile, EZ-Heat integrates seamlessly into your floor without adding noticeable height.
Unlike bulkier systems that require thick concrete layers, EZ-Heat is designed for a more streamlined installation. Under most floating floors including laminate, engineered wood, and LVP, the system can often be installed without any concrete layer at all.
The result is faster installation, lower installation costs, reduced floor buildup, and greater flexibility for both new builds and renovations.
Ideal for Heating
Your Whole Home
Most electric radiant systems are limited to small areas due to high energy consumption, while hydronic systems require complex installation and ongoing maintenance.
EZ-Heat bridges that gap. It's efficient enough to heat large spaces as a primary system, yet flexible enough for smaller applications like bathrooms and targeted comfort zones, all within a single, maintenance-free solution.
Even Heat. Consistent Comfort.
Traditional cable and hydronic systems can create uneven floor temperatures due to limited surface contact and inconsistent heat distribution.
EZ-Heat's flat Amorphous Metal Tape design spreads heat evenly across the floor surface, delivering a more balanced and comfortable radiant heating experience throughout the space.
The result is consistent warmth underfoot, improved comfort, and more efficient overall system performance.
Designed for
Every Floor Type
EZ-Heat system is designed to integrate seamlessly with a wide range of flooring applications. Whether installed beneath tile, floating floors, or glued-down surfaces, the system delivers efficient radiant heat with flexible installation methods to suit virtually any project.
Under Tile
The list below is the layers (top to bottom) of the image above.
- Tiles
- Thinset Mortar
- EZ-Heat Mats
- Insulation Backer board
- Subfloor (Concrete or Wood)
- Tiles
- Thinset Mortar
- EZ-Heat Mats
- Insulation Backer board
- Subfloor (Concrete or Wood)
Under Tile: Ideal for tile and stone applications using traditional thinset installation methods.
Under Floating Floors (Dry Installation)
Ideal for tile and stone applications using traditional thinset installation methods. The list below is the layers (top to bottom) of the image above.
- Floating Floor
- EZ-Heat Mats
- Insulating Underpad
- Subfloor (Concrete or Wood)
- Floating Floor
- EZ-Heat Mats
- Insulating Underpad
- Subfloor (Concrete or Wood)
Under Floating Floors (Dry Installation): No concrete layer required. Perfect for laminate, engineered wood, and LVP flooring systems.
Under Glued-Down Floors
No concrete layer required. Perfect for laminate, engineered wood, and LVP flooring systems. The list below is the layers (top to bottom) of the image above.
- Glued Down Floor
- Self Levelling Cement
- EZ-Heat Mats
- Insulation Backer Board
- Subfloor (Concrete or Wood)
- Glued Down Floor
- Self Levelling Cement
- EZ-Heat Mats
- Insulation Backer Board
- Subfloor (Concrete or Wood)
Under Glued-Down Floors: Compatible with glued-down flooring systems while maintaining efficient heat transfer and minimal floor buildup.
See EZ-Heat in Action
Project Gallery
Choose the Right EZ-Heat System for Your Project
The EZ-Heat system is available in two power output options, each designed for specific heating applications. Whether you’re looking for an efficient supplemental floor warming solution or a high-performance primary heating system, EZ-Heat offers a configuration tailored to your project’s needs. Choose the system that best matches your space, comfort goals, and heating requirements.
EZ-Heat ECO
7W/SqFt System
Supplemental Heating & Comfort Applications. Best suited for:
- Spaces with an existing heat source
- Supplemental floor warming
- Projects with limited available amperage
- Primary heating applications with heat loss of 5W/sqft or less
Mat Sizes
| Width (in.) | Length (ft.) | Voltage Options |
|---|---|---|
| 20 | 3 | 120V |
| 20 | 4 | 120V |
| 20 | 5 | 120V |
| 20 | 6 | 120V/240V |
| 20 | 7 | 120V/240V |
| 20 | 8 | 120V/240V |
| 20 | 9 | 120V//240V |
| 20 | 10 | 120V/240V |
| 20 | 11 | 120V/240V |
| 20 | 12 | 120V/240V |
| 20 | 13 | 120V/240V |
| 20 | 14 | 120V/240V |
| 20 | 15 | 120V/240V |
| 20 | 16 | 240V |
| 20 | 17 | 240V |
| 20 | 18 | 240V |
| 20 | 19 | 240V |
| 20 | 20 | 240V |
| 20 | 21 | 240V |
| 20 | 22 | 240V |
| 20 | 23 | 240V |
| 36 | 3 | 120V/240V |
| 36 | 4 | 120V/240V |
| 36 | 5 | 120V/240V |
| 36 | 6 | 120V/240V |
| 36 | 7 | 120V/240V |
| 36 | 8 | 120V/240V |
| 36 | 9 | 240V |
| 36 | 10 | 240V |
| 36 | 11 | 240V |
| 36 | 12 | 240V |
| 36 | 13 | 240V |
| 36 | 14 | 240V |
| 36 | 15 | 240V |
| 36 | 16 | 240V |
| 36 | 17 | 240V |
| 36 | 18 | 240V |
EZ-Heat Classic
14W/SqFt System
Primary Heating & Rapid Heat-Up Performance. Best suited for:
- Spaces without an existing heat source
- Primary heating applications
- Faster heat-up and reduced run times
Mat Sizes
| Width (in.) | Length (ft.) | Voltage Options |
|---|---|---|
| 20 | 3 | 120V |
| 20 | 3.3 | 240V |
| 20 | 4 | 120V/240V |
| 20 | 5 | 120V/240V |
| 20 | 6 | 120V/240V |
| 20 | 7 | 120V/240V |
| 20 | 8 | 120V/240V |
| 20 | 9 | 120V//240V |
| 20 | 10 | 120V//240V |
| 20 | 11 | 120V/240V |
| 20 | 12 | 120V/240V |
| 20 | 13 | 240V |
| 20 | 14 | 240V |
| 20 | 15 | 240V |
| 20 | 16 | 240V |
| 20 | 17 | 240V |
| 20 | 18 | 240V |
| 20 | 19 | 240V |
| 20 | 20 | 240V |
| 20 | 21 | 240V |
| 20 | 22 | 240V |
| 20 | 23 | 240V |
| 36 | 3 | 120V/240V |
| 36 | 4 | 120V/240V |
| 36 | 5 | 120V/240V |
| 36 | 6 | 120V/240V |
| 36 | 7 | 120V/240V |
| 36 | 8 | 240V |
| 36 | 9 | 240V |
| 36 | 10 | 240V |
| 36 | 11 | 240V |
| 36 | 12 | 240V |
| 36 | 13 | 240V |
* For primary heat, minimum floor coverage should be at least 75%.
Downloads
What Customers Say
I'm really happy with the product. Zach was quick with solid answers to my questions and designed a system that worked for my space. It was easy to lay out and install myself. Shipped quickly and without issue. I did everything but install the circuit. Instructions were clear and easy to follow. Small hiccups (normal) were addressed and resolved. Canadian company as well, which is a big bonus. 100% would recommend.
Tony O.It’s amazing the difference from the floor without to the floor with. Our kids can play barefoot without having ice cold toes. Makes the basement feel a lot more enjoyable especially with how cold it’s been this winter. Overall very happy, it was easy to get a quote, they designed the flooring for the weird basement shape I had. The cost was as expected and it arrived without hassle.
Courtney C.Awesome product! I got their EZ Heat System installed during my basement renovation and do I ever love it! It made the basement feel nice and cozy especially during the polar vortex days we had in Ontario this past winter. Installation was a breeze and I didn't have to use any concrete either. I highly recommend this heating system for anyone looking for a great heating solution for their basement or other areas of the house.
Zee J.We love our TruHeat System! After doing a lot of research and realizing these guys had something unique whereas everyone else had the same thing. We decided to go with truheat’s system for basement reno. It was very nice and cozy down there during this past winter. I highly recommend this company.
Sara E.Found Truheat to be genuinely responsive to all inquires and follow ups. Zach was very helpful. Installed the heating pads under luxury vinyl Cortec floor 1’x2’ tiles. Been 10 months now and so far all is good. Product is working as advertised. I believe I’m even shaving money off my gas bill by keeping my heat sucking cold kitchen toasty. But I also like the comfort of the warm floor and consistent heat. Two goals achieved! Thanks TruHeat!
Mark Q.Ready to Upgrade Your Heating System?
Frequently Asked Questions
What is the EZ-Heat system?
EZ-Heat is an advanced electric radiant floor heating system that uses ultra-thin amorphous metal heating ribbons attached to a fiberglass mesh. Its flat heating element provides broad contact with the floor surface, helping heat transfer more quickly and evenly than conventional round heating cables.
Can EZ-Heat be used as a primary heating system?
Yes. When properly designed and sized for the space, the EZ-Heat system can be used as a primary heat source. The EZ-Heat Classic system delivers 14 W/sq. ft. and is designed for whole-home and primary heating applications.
The EZ-Heat ECO system delivers 7 W/sq. ft. and is generally recommended for supplemental heating, comfort heating, or highly efficient spaces with low heat-loss requirements.
What is the difference between EZ-Heat ECO and EZ-Heat Classic?
EZ-Heat ECO operates at 7 W/sq. ft. and is ideal for supplemental heat, floor warming, and energy-efficient spaces with lower heating requirements.
EZ-Heat Classic operates at 14 W/sq. ft. and provides a higher heat output for faster warm-up and primary heating applications.
The appropriate system depends on the room size, available floor coverage, insulation, climate, and calculated heat loss.
What types of flooring can be installed over EZ-Heat?
EZ-Heat can be installed beneath many common flooring materials, including:
- Tile and stone
- Engineered hardwood
- Laminate
- Luxury vinyl flooring
- Glued-down flooring
- Floating floor systems
Always confirm that the selected flooring product is approved by its manufacturer for use with radiant floor heating.
Can EZ-Heat be installed under floating floors without concrete?
Yes. EZ-Heat offers a dry installation option beneath compatible floating floors, allowing the system to be installed without embedding it in a concrete or self-levelling layer.
This installation method can reduce installation time, material costs, and overall floor buildup. EZ-Heat may also be installed using traditional embedded methods when preferred or required by the flooring manufacturer.
How thin is the EZ-Heat system?
The EZ-Heat heating mat is approximately 2.5 mm thick. Its low-profile design helps minimize changes to the finished floor height and makes it suitable for both renovations and new construction.
How quickly does EZ-Heat warm the floor?
EZ-Heat is designed to respond quickly. The low-mass amorphous metal heating ribbon reaches its operating temperature rapidly and transfers heat efficiently across its flat surface.
Actual warm-up time will vary depending on the flooring material, insulation, subfloor construction, room temperature, and thermostat settings.
Why does EZ-Heat use a flat heating ribbon instead of a round cable?
A flat heating ribbon creates more direct surface contact with the surrounding flooring assembly. This helps distribute heat over a wider area and transfer it toward the floor surface more efficiently.
Compared with a round heating cable, the flat ribbon also creates a lower-profile installation with fewer concentrated hot spots.
How energy-efficient is the EZ-Heat system?
EZ-Heat is designed to heat the floor quickly and reduce the amount of time the system needs to operate. Its flat heating element provides broad heat distribution, while its low thermal mass allows it to respond faster than systems that must first heat a thick concrete layer.
Energy use will depend on the heat loss of the space, insulation, floor covering, thermostat settings, local climate, and electricity rates.
What percentage of the floor should be covered?
For primary heating applications, TruHeat generally recommends covering at least 75% of the available floor area.
Higher floor coverage provides more even heat distribution and allows the system to meet the room's heating requirements while operating at a comfortable floor temperature.
Can EZ-Heat be installed under cabinets, vanities, or permanent fixtures?
The heating mats should generally not be installed beneath permanently fixed cabinets, kitchen islands, built-in vanities, walls, or other areas where heat may become trapped.
The floor layout should be planned around permanent fixtures before the mat sizes are selected.
Can furniture and area rugs be placed over the heated floor?
Most furniture can be placed over a radiant-heated floor when there is adequate airflow beneath it. Large furniture with a solid base, thick rugs, rubber-backed mats, or other highly insulating materials may trap heat and should be avoided unless approved by the flooring and furniture manufacturers.
Can the EZ-Heat mats be cut?
The fiberglass mesh may be cut and turned to help the mat fit the room layout, but the heating ribbon itself must never be cut, shortened, crossed, overlapped, or damaged.
Mat sizes should be selected carefully based on the available heating area.
Can multiple EZ-Heat mats be connected to one thermostat?
Yes. Multiple mats can be connected in parallel and controlled by a single thermostat, provided the combined electrical load does not exceed the thermostat's rated capacity.
For larger installations, power modules, relays, contactors, or multiple control zones may be required.
Does the system include a thermostat?
EZ-Heat systems can be paired with a compatible floor-heating thermostat featuring a floor sensor and built-in Class A GFCI protection.
Programmable and Wi-Fi-enabled control options are available, depending on the project requirements.
Why is a floor sensor required?
The floor sensor allows the thermostat to monitor and control the floor temperature. This helps maintain comfort, protect the flooring material, and prevent the floor from exceeding the recommended temperature.
The sensor is installed between the heating ribbons and should be placed inside a conduit whenever possible so it can be replaced if necessary.
Is EZ-Heat available in both 120V and 240V?
Yes. EZ-Heat mats are available in both 120V and 240V configurations.
The appropriate voltage will depend on the project size, electrical service, mat availability, and circuit design.
Can EZ-Heat be installed in bathrooms and other wet areas?
Yes. EZ-Heat can be installed in bathrooms and other suitable interior areas when it is installed according to the product instructions and all applicable electrical and building codes.
A properly installed waterproofing system may also be required depending on the room and flooring assembly.
Can EZ-Heat be installed in showers?
Installation inside a shower area depends on the specific system configuration, local electrical code, waterproofing method, and product approvals.
Contact TruHeat before including heated mats inside a shower enclosure
Can EZ-Heat be installed over concrete or wood subfloors?
Yes. EZ-Heat can be installed over properly prepared concrete and wood subfloors.
The surface must be clean, stable, level, and suitable for the selected installation method. Insulation beneath the heating system is strongly recommended where practical, especially over concrete slabs.
Is insulation required beneath the system?
Insulation is not always mandatory, but it is highly recommended. Proper insulation reduces downward heat loss, improves warm-up time, and helps lower operating costs.
This is especially important over concrete slabs, garages, basements, crawlspaces, and other unheated areas.
Can EZ-Heat be installed during a renovation?
Yes. The system's low-profile construction makes it well suited to renovation projects where minimizing additional floor height is important.
It can also be used in new construction, additions, basements, bathrooms, kitchens, bedrooms, and whole-home heating projects.
Who should install the electrical connections?
The heating mats may be laid out by a qualified installer in accordance with the installation instructions, but all permanent electrical connections must be completed by a licensed electrician in accordance with local electrical codes.
Does TruHeat provide system design and layout assistance?
Yes. TruHeat can help review floor plans, calculate the available heating area, recommend mat sizes, determine electrical requirements, and prepare a system layout for the project.
Providing accurate floor plans and the locations of permanent fixtures helps ensure the system is properly designed.
What warranty is included with EZ-Heat?
The EZ-Heat system is backed by a 15-year limited warranty when it is installed, tested, and documented in accordance with TruHeat's installation requirements.
Refer to the official warranty documentation for complete terms, conditions, and exclusions.
What testing should be completed during installation?
The heating mats should be electrically tested before installation, during installation, and after the finished flooring has been installed.
Resistance readings should be recorded and compared with the values shown on the product label. A continuity alarm is also recommended during flooring installation to immediately identify accidental damage.
What happens if a heating mat is damaged?
Do not energize or cover a damaged heating mat. Stop the installation and contact TruHeat for guidance.
In many cases, damage can be located and professionally repaired before the finished floor is completed.
How do I know which EZ-Heat system is right for my project?
The correct system depends on the size of the space, desired heating performance, available floor coverage, floor construction, insulation level, electrical capacity, and calculated heat loss.
Contact TruHeat with your floor plans and project details for a system recommendation and layout.